{"id":217,"date":"2024-04-17T20:40:43","date_gmt":"2024-04-17T18:40:43","guid":{"rendered":"https:\/\/staging.phasetophase.nl\/en\/?page_id=217"},"modified":"2024-04-28T21:35:41","modified_gmt":"2024-04-28T19:35:41","slug":"gaia-lv-network-design","status":"publish","type":"page","link":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/gaia-lv-network-design\/","title":{"rendered":"Gaia LV Network Design"},"content":{"rendered":"<div class=\"hero\">\n\t<div class=\"container\">\n\t\t<div class=\"hero__content space-content\">\n\t\t\t\t\t\t\t<h1>Gaia LV Network Design<\/h1>\n\t\t\t\t\t\t\t\t\t\t<p>Gaia LV Network Design is a program for planning, designing and evaluation distribution, and industrial low-voltage grids.\u00a0Gaia LV Network Design makes it easy to determine the voltage management, system load and the earthing\/contact safety of the grid.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<figure class=\"hero__image\">\n\t\t\t\t<img decoding=\"async\" width=\"883\" height=\"795\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Gaia-LV-Network-Design-Kirchhoff-1.png\" class=\"attachment-full size-full\" alt=\"\" loading=\"lazy\" srcset=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Gaia-LV-Network-Design-Kirchhoff-1.png 883w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Gaia-LV-Network-Design-Kirchhoff-1-300x270.png 300w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Gaia-LV-Network-Design-Kirchhoff-1-768x691.png 768w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Gaia-LV-Network-Design-Kirchhoff-1-1x1.png 1w\" sizes=\"auto, (max-width: 883px) 100vw, 883px\" \/>\t\t\t\t<figcaption class=\"hero__image-caption\">\n\t\t\t\t\tGustav Robert Kirchhoff\t\t\t\t<\/figcaption>\n\t\t\t<\/figure>\n\t\t\t<\/div>\n<\/div>\n\n\n<section class=\"block ptp-columns\">\n\t<div class=\"container\">\n\t\t\n<div class=\"ptp-columns-row layout-3-2\">\n\t\n<div class=\"ptp-column\">\n\t\n\n<p>In the coming years, analyses in low-voltage grids will play an increasingly important role due to the decentralisation of generation and changing user profiles. Gaia LV Network Design gives the user all the tools to facilitate the energy transition through its user-friendliness, functionalities and visualization. A new advanced modular load model enables them to easily determine how future-proof their low-voltage grids are.<\/p>\n\n<\/div>\n\n\n<div class=\"ptp-column\">\n\t\n<div class=\"ptp-image\">\n\t\t\t<figure class=\"ptp-image__image-wrapper\">\n\t\t\t<img decoding=\"async\" width=\"1475\" height=\"1475\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-design-mandala.png\" class=\"ptp-image__image\" alt=\"\" loading=\"lazy\" srcset=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-design-mandala.png 1475w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-design-mandala-300x300.png 300w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-design-mandala-1024x1024.png 1024w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-design-mandala-150x150.png 150w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-design-mandala-768x768.png 768w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-design-mandala-100x100.png 100w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-design-mandala-1x1.png 1w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-design-mandala-400x400.png 400w\" sizes=\"auto, (max-width: 1475px) 100vw, 1475px\" \/>\t\t<\/figure>\n\t<\/div>\n\n<\/div>\n\n<\/div>\n\n\n<div class=\"ptp-columns-row layout-100\">\n\t\n<div class=\"ptp-column\">\n\t\n\n<h2 class=\"wp-block-heading\" id=\"h-safety-and-modelling\">Safety and modelling<\/h2>\n\n<\/div>\n\n<\/div>\n\n\n<div class=\"ptp-columns-row layout-50-50\">\n\t\n<div class=\"ptp-column\">\n\t\n\n<p>Calculating the low-voltage grids loads during and after the energy transition with a completely new modular load model.<\/p>\n\n\n\n<p>One of the starting points in the development of Gaia LV Network Design was to guarantee safety in both TT and TN earthed grids.<\/p>\n\n\n\n<p>In order to be able to calculate asymmetrical loads and short-circuits, Phase to Phase has developed a unique nine-conductor load flow.<\/p>\n\n<\/div>\n\n\n<div class=\"ptp-column\">\n\t\n<div class=\"ptp-image has-frame\">\n\t\t\t<figure class=\"ptp-image__image-wrapper\">\n\t\t\t<?xml version=\"1.0\" encoding=\"UTF-8\"?> <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"132\" height=\"56\" viewBox=\"0 0 132 56\" fill=\"none\"><g style=\"mix-blend-mode:multiply\"><path d=\"M131.979 55.8916L0.844722 0.988293L131.979 0.988281L131.979 55.8916Z\" fill=\"#69A8BA\"><\/path><\/g><\/svg> <img decoding=\"async\" width=\"2400\" height=\"1500\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-desing_aanraakveiligheid.jpg\" class=\"ptp-image__image\" alt=\"\" loading=\"lazy\" srcset=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-desing_aanraakveiligheid.jpg 2400w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-desing_aanraakveiligheid-300x188.jpg 300w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-desing_aanraakveiligheid-1024x640.jpg 1024w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-desing_aanraakveiligheid-768x480.jpg 768w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-desing_aanraakveiligheid-1536x960.jpg 1536w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-desing_aanraakveiligheid-2048x1280.jpg 2048w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-desing_aanraakveiligheid-1x1.jpg 1w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/gaia-lv-network-desing_aanraakveiligheid-400x250.jpg 400w\" sizes=\"auto, (max-width: 2400px) 100vw, 2400px\" \/><?xml version=\"1.0\" encoding=\"UTF-8\"?> <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"270\" height=\"49\" viewBox=\"0 0 270 49\" fill=\"none\"><g style=\"mix-blend-mode:multiply\"><path d=\"M269.332 48.5605L0.0935669 48.5606L0.0935626 -0.00607998L168.811 11.1935L269.332 24.2772L269.332 48.5605Z\" fill=\"#93CDE5\"><\/path><\/g><\/svg> \t\t<\/figure>\n\t<\/div>\n\n<\/div>\n\n<\/div>\n\n\t<\/div>\n<\/section>\n\n\n<section class=\"block ptp-columns\">\n\t<div class=\"container\">\n\t\t\n<div class=\"ptp-columns-row layout-50-50\">\n\t\n<div class=\"ptp-column\">\n\t\n\n<h2 class=\"wp-block-heading\" id=\"h-geographical-display-of-load-flow-information\">Geographical display of load flow information<\/h2>\n\n\n\n<p>With&nbsp;Vision Grid <a href=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-grid-navigator\/\">Vision Grid Navigator<\/a>Navigator&nbsp;you can switch between schematic and geographical display. The program provides useful insight by linking load flow results from Gaia LV Network Design to GIS data.<\/p>\n\n\n<div class=\"button-group\">\n\t\n\t<a href=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-grid-navigator\/\" class=\"btn\" target=\"_self\">\n\t\tVision Grid Navigator\t<\/a>\n\t\n<\/div>\n\n<\/div>\n\n\n<div class=\"ptp-column\">\n\t\n<div class=\"ptp-image\">\n\t\t\t<figure class=\"ptp-image__image-wrapper\">\n\t\t\t<img decoding=\"async\" width=\"700\" height=\"467\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-grid-navigator_3dscene.jpg\" class=\"ptp-image__image\" alt=\"\" loading=\"lazy\" srcset=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-grid-navigator_3dscene.jpg 700w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-grid-navigator_3dscene-300x200.jpg 300w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-grid-navigator_3dscene-1x1.jpg 1w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/>\t\t<\/figure>\n\t<\/div>\n\n<\/div>\n\n<\/div>\n\n\t<\/div>\n<\/section>\n\n\n<section class=\"block ptp-columns\">\n\t<div class=\"container\">\n\t\t\n<div class=\"ptp-columns-row layout-50-50\">\n\t\n<div class=\"ptp-column\">\n\t\n\n<h2 class=\"wp-block-heading\" id=\"h-functionality\">Functionality<\/h2>\n\n\n\n<p>Gaia LV Network Design is an integrated program for analysis and design of LV-distribution networks. Interface and functionality have been developed in collaboration with distribution companies and industry. This makes Gaia a unique package for analysis of low-voltage installations.<\/p>\n\n<\/div>\n\n\n<div class=\"ptp-column\">\n\t\n\n<h2 class=\"wp-block-heading\" id=\"h-ease-of-use\">Ease of use<\/h2>\n\n\n\n<p>Because Gaia LV Network Design should be able to be used by both frequent and occasional users, it is very user-friendly. The program is menu-driven and uses an understandable interface, minimizing the risk of errors.<\/p>\n\n<\/div>\n\n<\/div>\n\n\n<div class=\"ptp-columns-row layout-50-50\">\n\t\n<div class=\"ptp-column\">\n\t\n\n<h2 class=\"wp-block-heading\" id=\"h-asymmetrical-grids\">Asymmetrical grids<\/h2>\n\n\n\n<p>Low-voltage grids are often asymmetrical. Due to the neutral conductor and complex earthing, the application of symmetrical component methods isn&#8217;t possible. Gaia LV Network Design uses a unique model in which all conductors including the mutual connections are covered. The total electrical system can be extensively configured due to the many switching possibilities.<\/p>\n\n<\/div>\n\n\n<div class=\"ptp-column\">\n\t\n\n<h2 class=\"wp-block-heading\" id=\"h-contact-safety\">Contact safety<\/h2>\n\n\n\n<p>Gaia LV Network Design was specifically developed to ensure contact safety in both TT and TN systems. The contact safety module calculates the safety for people in a low voltage network. The safety is determined by the height of the voltage and the timely switching of the short circuit.<\/p>\n\n<\/div>\n\n\n<div class=\"ptp-column\">\n\t\n\n<h2 class=\"wp-block-heading\" id=\"h-power-quality\">Power quality<\/h2>\n\n\n\n<p>With Gaia LV Network Design different aspects of power quality can be analyzed, like voltage variation, voltage asymmetry, voltage dips, grid flicker and harmonic pollution.<br>The voltage level is calculated using a stochastic load flow, taking into account expected average loads and extremes. The calculation is based on the complete asymmetrical grid.<\/p>\n\n<\/div>\n\n<\/div>\n\n\t<\/div>\n<\/section>\n\n\n<div class=\"block link-list-wrapper\">\n\t<div class=\"container\">\n\t\t\n\n<h2 class=\"wp-block-heading\" id=\"h-downloads-en-documentatie\">Downloads en documentatie<\/h2>\n\n\n\n<p>You can download the latest version of Vision Network Analysis here. Without a license, Vision Network Analysis can only be used in demonstration mode. For a license or more information, contact&nbsp;<a href=\"mailto:info@phasetophase.nl\">info@phasetophase.nl<\/a>.<\/p>\n\n\n<div class=\"link-list-container\">\n\t<ul class=\"link-list\">\n\t\t\n\t<li class=\"link-list__item\">\n\t\t<a href=\"https:\/\/www.phasetophase.nl\/en\/downloadportal\/\" class=\"\" target=\"_blank\">\n\t\t\t<span>Download Gaia LV Network Design<\/span>\n\t\t\t <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"11\" height=\"19\" viewBox=\"0 0 11 19\" fill=\"none\"><path d=\"M1.54785 17.3069L9.46204 9.3927L1.54785 1.47852\" stroke=\"white\" stroke-width=\"2.63806\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \t\t<\/a>\n\t<\/li>\n\t\n\n\t<li class=\"link-list__item\">\n\t\t<a href=\"https:\/\/youtu.be\/kYaRHie5bdE?si=KSR-craG6qDRNK4V\" class=\"\" target=\"_blank\">\n\t\t\t<span>Tutorials<\/span>\n\t\t\t <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"11\" height=\"19\" viewBox=\"0 0 11 19\" fill=\"none\"><path d=\"M1.54785 17.3069L9.46204 9.3927L1.54785 1.47852\" stroke=\"white\" stroke-width=\"2.63806\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \t\t<\/a>\n\t<\/li>\n\t\n\n\t<li class=\"link-list__item\">\n\t\t<a href=\"https:\/\/www.phasetophase.nl\/en\/downloadportal\/\" class=\"\" target=\"_self\">\n\t\t\t<span>Download sentinel-driver (voor SuperPro-PC-sleutel)<\/span>\n\t\t\t <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"11\" height=\"19\" viewBox=\"0 0 11 19\" fill=\"none\"><path d=\"M1.54785 17.3069L9.46204 9.3927L1.54785 1.47852\" stroke=\"white\" stroke-width=\"2.63806\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \t\t<\/a>\n\t<\/li>\n\t\n\t<\/ul>\n<\/div>\n\n\t<\/div>\n<\/div>\n\n\n<section class=\"block block-slider\">\n\t\t\t<div class=\"container\">\n\t\t\t<h2>Our products<\/h2>\n\t\t<\/div>\n\t\t<div class=\"cards-slider swiper\">\n\t\t<div class=\"swiper-wrapper\">\n\t\t\t\n<div class=\"swiper-slide\">\n\t\n<article>\n\t\t\t<a href=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-network-analysis\/\" target=\"_self\" class=\"card card--slider\">\n\t\t\t\n\t\t\t\t\t\t\t<figure class=\"card__image\">\n\t\t\t\t\t<div class=\"image__inner\">\n\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"250\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Network-Analysis_knop-400x250.png\" class=\"attachment-card size-card\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/figure>\n\t\t\t\t\t\t<div class=\"card__content\">\n\t\t\t\t<h3 class=\"card__title\">Vision Network Analysis<\/h3>\t\t\t\t\t\t\t\t\t\t\t\t\t<p class=\"card__paragraph\">Planning, design and control of transport, distribution and industrial grids<\/p>\n\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t\t <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"32\" height=\"33\" viewBox=\"0 0 32 33\" fill=\"none\"><path d=\"M12.2144 24.3889L20.1285 16.4747L12.2144 8.56055\" stroke=\"#5D5D61\" stroke-width=\"2.63806\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \n\t\t\t\t<\/a>\n\t<\/article>\n<\/div>\n\n\n<div class=\"swiper-slide\">\n\t\n<article>\n\t\t\t<a href=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cloud-solution\/\" target=\"_self\" class=\"card card--slider\">\n\t\t\t\n\t\t\t\t\t\t\t<figure class=\"card__image\">\n\t\t\t\t\t<div class=\"image__inner\">\n\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"250\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Cloud-Solutionrknop-400x250.png\" class=\"attachment-card size-card\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/figure>\n\t\t\t\t\t\t<div class=\"card__content\">\n\t\t\t\t<h3 class=\"card__title\">Vision Cloud Solution<\/h3>\t\t\t\t\t\t\t\t\t\t\t\t\t<p class=\"card__paragraph\">Detailed insight into entire distribution networks.<\/p>\n\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t\t <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"32\" height=\"33\" viewBox=\"0 0 32 33\" fill=\"none\"><path d=\"M12.2144 24.3889L20.1285 16.4747L12.2144 8.56055\" stroke=\"#5D5D61\" stroke-width=\"2.63806\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \n\t\t\t\t<\/a>\n\t<\/article>\n<\/div>\n\n\n<div class=\"swiper-slide\">\n\t\n<article>\n\t\t\t<a href=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-grid-navigator\/\" target=\"_self\" class=\"card card--slider\">\n\t\t\t\n\t\t\t\t\t\t\t<figure class=\"card__image\">\n\t\t\t\t\t<div class=\"image__inner\">\n\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"250\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Grid-Navigator_knop-400x250.png\" class=\"attachment-card size-card\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/figure>\n\t\t\t\t\t\t<div class=\"card__content\">\n\t\t\t\t<h3 class=\"card__title\">Vision Grid Navigator<\/h3>\t\t\t\t\t\t\t\t\t\t\t\t\t<p class=\"card__paragraph\">Information from power grids on geographical backgrounds<\/p>\n\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t\t <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"32\" height=\"33\" viewBox=\"0 0 32 33\" fill=\"none\"><path d=\"M12.2144 24.3889L20.1285 16.4747L12.2144 8.56055\" stroke=\"#5D5D61\" stroke-width=\"2.63806\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \n\t\t\t\t<\/a>\n\t<\/article>\n<\/div>\n\n\n<div class=\"swiper-slide\">\n\t\n<article>\n\t\t\t<a href=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cable-analysis\/\" target=\"_self\" class=\"card card--slider\">\n\t\t\t\n\t\t\t\t\t\t\t<figure class=\"card__image\">\n\t\t\t\t\t<div class=\"image__inner\">\n\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"250\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Cable-Analysis_knop-400x250.png\" class=\"attachment-card size-card\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/figure>\n\t\t\t\t\t\t<div class=\"card__content\">\n\t\t\t\t<h3 class=\"card__title\">Vision Cable Analysis<\/h3>\t\t\t\t\t\t\t\t\t\t\t\t\t<p class=\"card__paragraph\">Current rating of single and three phase cables based on IEC 60287 and 60853.<\/p>\n\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t\t <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"32\" height=\"33\" viewBox=\"0 0 32 33\" fill=\"none\"><path d=\"M12.2144 24.3889L20.1285 16.4747L12.2144 8.56055\" stroke=\"#5D5D61\" stroke-width=\"2.63806\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \n\t\t\t\t<\/a>\n\t<\/article>\n<\/div>\n\n\n<div class=\"swiper-slide\">\n\t\n<article>\n\t\t\t<a href=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-fault-finder\/\" target=\"_self\" class=\"card card--slider\">\n\t\t\t\n\t\t\t\t\t\t\t<figure class=\"card__image\">\n\t\t\t\t\t<div class=\"image__inner\">\n\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"250\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Fault-Finder_knop-400x250.png\" class=\"attachment-card size-card\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/figure>\n\t\t\t\t\t\t<div class=\"card__content\">\n\t\t\t\t<h3 class=\"card__title\">Vision Fault Finder<\/h3>\t\t\t\t\t\t\t\t\t\t\t\t\t<p class=\"card__paragraph\">Fast fault localisation by using measurements and simulation<\/p>\n\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t\t <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"32\" height=\"33\" viewBox=\"0 0 32 33\" fill=\"none\"><path d=\"M12.2144 24.3889L20.1285 16.4747L12.2144 8.56055\" stroke=\"#5D5D61\" stroke-width=\"2.63806\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \n\t\t\t\t<\/a>\n\t<\/article>\n<\/div>\n\n\t\t<\/div>\n\t\t<button class=\"slider-block__button-prev\">\n\t\t\t<?xml version=\"1.0\" encoding=\"UTF-8\"?> <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"49\" height=\"49\" viewBox=\"0 0 49 49\" fill=\"none\"><path d=\"M2.12156 2.22667L45.7728 0.605469L48.0963 48.6582H0.951172L2.12156 2.22667Z\" fill=\"#0077B0\"><\/path><path d=\"M21 30.4834L27 24.4834L21 18.4834\" stroke=\"white\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \t\t<\/button>\n\t\t<button class=\"slider-block__button-next\">\n\t\t\t<?xml version=\"1.0\" encoding=\"UTF-8\"?> <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"49\" height=\"49\" viewBox=\"0 0 49 49\" fill=\"none\"><path d=\"M2.12156 2.22667L45.7728 0.605469L48.0963 48.6582H0.951172L2.12156 2.22667Z\" fill=\"#0077B0\"><\/path><path d=\"M21 30.4834L27 24.4834L21 18.4834\" stroke=\"white\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \t\t<\/button>\n\t\t<div class=\"swiper-pagination\"><\/div>\n\t<\/div>\n<\/section>\n\n\n<section class=\"call-to-action\">\n\t<div class=\"container\">\n\t\t<div class=\"column\">\n\t\t\t\n\n<h2 class=\"wp-block-heading\" id=\"h-instant-answer-to-your-question-please-contact-us\">Instant answer to your question?<br>Please contact us<\/h2>\n\n\t\t<\/div>\n\t\t<div class=\"column\">\n\t\t\t\t\t\t\t<a href=\"https:\/\/www.phasetophase.nl\/en\/contact\/\" class=\"button button--secondary\">\n\t\t\t\t\tContact us\t\t\t\t<\/a>\n\t\t\t\t\t<\/div>\n\t<\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":203,"parent":175,"menu_order":7,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"editor_notices":[],"footnotes":""},"class_list":["post-217","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.6 (Yoast SEO v27.6) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Gaia LV Network Design - Phase to Phase<\/title>\n<meta name=\"description\" content=\"Gaia LV Network Design is a program for planning, designing and evaluation distribution, and industrial low-voltage grids.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/gaia-lv-network-design\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Gaia LV Network Design\" \/>\n<meta property=\"og:description\" content=\"Gaia LV Network Design is a program for planning, designing and evaluation distribution, and industrial low-voltage grids.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/gaia-lv-network-design\/\" \/>\n<meta property=\"og:site_name\" content=\"Phase to Phase\" \/>\n<meta property=\"article:modified_time\" content=\"2024-04-28T19:35:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Gaia-LV-Network-Design-Kirchhoff-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"883\" \/>\n\t<meta property=\"og:image:height\" content=\"795\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/gaia-lv-network-design\\\/\",\"url\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/gaia-lv-network-design\\\/\",\"name\":\"Gaia LV Network Design - Phase to Phase\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/gaia-lv-network-design\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/gaia-lv-network-design\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.phasetophase.nl\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2024\\\/04\\\/Gaia-LV-Network-Design-Kirchhoff-1.png\",\"datePublished\":\"2024-04-17T18:40:43+00:00\",\"dateModified\":\"2024-04-28T19:35:41+00:00\",\"description\":\"Gaia LV Network Design is a program for planning, designing and evaluation distribution, and industrial low-voltage grids.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/gaia-lv-network-design\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/gaia-lv-network-design\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/gaia-lv-network-design\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.phasetophase.nl\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2024\\\/04\\\/Gaia-LV-Network-Design-Kirchhoff-1.png\",\"contentUrl\":\"https:\\\/\\\/www.phasetophase.nl\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2024\\\/04\\\/Gaia-LV-Network-Design-Kirchhoff-1.png\",\"width\":883,\"height\":795},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/gaia-lv-network-design\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products and services\",\"item\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Products\",\"item\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Gaia LV Network Design\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/\",\"name\":\"Phase to Phase\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Gaia LV Network Design - Phase to Phase","description":"Gaia LV Network Design is a program for planning, designing and evaluation distribution, and industrial low-voltage grids.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/gaia-lv-network-design\/","og_locale":"en_US","og_type":"article","og_title":"Gaia LV Network Design","og_description":"Gaia LV Network Design is a program for planning, designing and evaluation distribution, and industrial low-voltage grids.","og_url":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/gaia-lv-network-design\/","og_site_name":"Phase to Phase","article_modified_time":"2024-04-28T19:35:41+00:00","og_image":[{"width":883,"height":795,"url":"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Gaia-LV-Network-Design-Kirchhoff-1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/gaia-lv-network-design\/","url":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/gaia-lv-network-design\/","name":"Gaia LV Network Design - Phase to Phase","isPartOf":{"@id":"https:\/\/www.phasetophase.nl\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/gaia-lv-network-design\/#primaryimage"},"image":{"@id":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/gaia-lv-network-design\/#primaryimage"},"thumbnailUrl":"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Gaia-LV-Network-Design-Kirchhoff-1.png","datePublished":"2024-04-17T18:40:43+00:00","dateModified":"2024-04-28T19:35:41+00:00","description":"Gaia LV Network Design is a program for planning, designing and evaluation distribution, and industrial low-voltage grids.","breadcrumb":{"@id":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/gaia-lv-network-design\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/gaia-lv-network-design\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/gaia-lv-network-design\/#primaryimage","url":"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Gaia-LV-Network-Design-Kirchhoff-1.png","contentUrl":"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Gaia-LV-Network-Design-Kirchhoff-1.png","width":883,"height":795},{"@type":"BreadcrumbList","@id":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/gaia-lv-network-design\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.phasetophase.nl\/en\/"},{"@type":"ListItem","position":2,"name":"Products and services","item":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/"},{"@type":"ListItem","position":3,"name":"Products","item":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/"},{"@type":"ListItem","position":4,"name":"Gaia LV Network Design"}]},{"@type":"WebSite","@id":"https:\/\/www.phasetophase.nl\/en\/#website","url":"https:\/\/www.phasetophase.nl\/en\/","name":"Phase to Phase","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.phasetophase.nl\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/pages\/217","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/comments?post=217"}],"version-history":[{"count":6,"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/pages\/217\/revisions"}],"predecessor-version":[{"id":361,"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/pages\/217\/revisions\/361"}],"up":[{"embeddable":true,"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/pages\/175"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/media\/203"}],"wp:attachment":[{"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/media?parent=217"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}