{"id":219,"date":"2024-04-17T20:41:33","date_gmt":"2024-04-17T18:41:33","guid":{"rendered":"https:\/\/staging.phasetophase.nl\/en\/?page_id=219"},"modified":"2024-04-28T21:34:38","modified_gmt":"2024-04-28T19:34:38","slug":"vision-cable-analysis","status":"publish","type":"page","link":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cable-analysis\/","title":{"rendered":"Vision Cable Analysis"},"content":{"rendered":"<div class=\"hero\">\n\t<div class=\"container\">\n\t\t<div class=\"hero__content space-content\">\n\t\t\t\t\t\t\t<h1>Vision Cable Analysis<\/h1>\n\t\t\t\t\t\t\t\t\t\t<p>Vision Cable Analysis enables you to easily calculate the load capacity of cables. The program uses the IEC 60287 (stationary load capacity) and IEC 60853 standard (dynamic load capacity), allowing it to calculate both &#039;simple&#039; continuous as well as temporary and cyclical loads.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<figure class=\"hero__image\">\n\t\t\t\t<img decoding=\"async\" width=\"897\" height=\"795\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Cable-Analysis-Ampere-1.png\" class=\"attachment-full size-full\" alt=\"\" loading=\"lazy\" srcset=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Cable-Analysis-Ampere-1.png 897w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Cable-Analysis-Ampere-1-300x266.png 300w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Cable-Analysis-Ampere-1-768x681.png 768w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Cable-Analysis-Ampere-1-1x1.png 1w\" sizes=\"auto, (max-width: 897px) 100vw, 897px\" \/>\t\t\t\t<figcaption class=\"hero__image-caption\">\n\t\t\t\t\tAndr\u00e9-Marie Amp\u00e8re\t\t\t\t<\/figcaption>\n\t\t\t<\/figure>\n\t\t\t<\/div>\n<\/div>\n\n\n<section class=\"block ptp-columns\">\n\t<div class=\"container\">\n\t\t\n<div class=\"ptp-columns-row layout-50-50\">\n\t\n<div class=\"ptp-column\">\n\t\n\n<h2 class=\"wp-block-heading\" id=\"h-cable-and-surroundings\">Cable and surroundings<\/h2>\n\n\n<div class=\"ptp-image\">\n\t\t\t<figure class=\"ptp-image__image-wrapper\">\n\t\t\t<img decoding=\"async\" width=\"1290\" height=\"864\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-Algemeen2.jpg\" class=\"ptp-image__image\" alt=\"\" loading=\"lazy\" srcset=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-Algemeen2.jpg 1290w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-Algemeen2-300x201.jpg 300w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-Algemeen2-1024x686.jpg 1024w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-Algemeen2-768x514.jpg 768w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-Algemeen2-1x1.jpg 1w\" sizes=\"auto, (max-width: 1290px) 100vw, 1290px\" \/>\t\t<\/figure>\n\t<\/div>\n\n\n\n<p>Vision Cable Analysis calculates the temperature of cables and their environment, taking into account the environment and possible external heat sources.<\/p>\n\n<\/div>\n\n\n<div class=\"ptp-column\">\n\t\n\n<h2 class=\"wp-block-heading\" id=\"h-cable-editor\">Cable editor<\/h2>\n\n\n<div class=\"ptp-image\">\n\t\t\t<figure class=\"ptp-image__image-wrapper\">\n\t\t\t<img decoding=\"async\" width=\"1453\" height=\"900\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-KabelTypeEditor.png\" class=\"ptp-image__image\" alt=\"\" loading=\"lazy\" srcset=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-KabelTypeEditor.png 1453w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-KabelTypeEditor-300x186.png 300w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-KabelTypeEditor-1024x634.png 1024w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-KabelTypeEditor-768x476.png 768w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-KabelTypeEditor-1x1.png 1w\" sizes=\"auto, (max-width: 1453px) 100vw, 1453px\" \/>\t\t<\/figure>\n\t<\/div>\n\n\n\n<p>Vision Cable Analysis comes with an extensive database of the most commonly used cables. Users can easily modify cables and define additional cable models.<\/p>\n\n<\/div>\n\n<\/div>\n\n\t<\/div>\n<\/section>\n\n\n<section class=\"block ptp-columns\">\n\t<div class=\"container\">\n\t\t\n<div class=\"ptp-columns-row layout-50-50\">\n\t\n<div class=\"ptp-column\">\n\t\n\n<h2 class=\"wp-block-heading\" id=\"h-iec-60287\">IEC 60287<\/h2>\n\n\n\n<p>The IEC 60287 standard describes the methods for calculating cable losses and the thermal resistance of the cable and its environment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-functionality\">Functionality<\/h3>\n\n\n\n<p>Vision Cable Analysis calculates:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Maximum current rating for multiple circuits of single and three core cables<\/li>\n\n\n\n<li>Temperature of all cables at each selected amperage<\/li>\n\n\n\n<li>Temperature of the surrounding soil<\/li>\n\n\n\n<li>Sensitivity analysis<\/li>\n<\/ul>\n\n\n\n<p>The results of the calculations are presented graphically, with any change or adjustment immediately visible.<\/p>\n\n<\/div>\n\n\n<div class=\"ptp-column\">\n\t\n<div class=\"ptp-image\">\n\t\t\t<figure class=\"ptp-image__image-wrapper\">\n\t\t\t<img decoding=\"async\" width=\"1290\" height=\"864\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-IEC60287-2.png\" class=\"ptp-image__image\" alt=\"\" loading=\"lazy\" srcset=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-IEC60287-2.png 1290w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-IEC60287-2-300x201.png 300w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-IEC60287-2-1024x686.png 1024w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-IEC60287-2-768x514.png 768w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-IEC60287-2-1x1.png 1w\" sizes=\"auto, (max-width: 1290px) 100vw, 1290px\" \/>\t\t<\/figure>\n\t<\/div>\n\n<\/div>\n\n<\/div>\n\n\t<\/div>\n<\/section>\n\n\n<section class=\"block ptp-columns\">\n\t<div class=\"container\">\n\t\t\n<div class=\"ptp-columns-row layout-50-50\">\n\t\n<div class=\"ptp-column\">\n\t\n\n<h2 class=\"wp-block-heading\" id=\"h-iec-60853\">IEC 60853<\/h2>\n\n\n\n<p>De IEC 60853 standard describes the methods for calculating of de cyclic cable rating and the emergency cable rating.<\/p>\n\n\n\n<p>The dynamic cable rating calculation is based on the fact that a cable, not conducting 100% of the maximum continuous current, has not reached its maximum temperature. Thanks to the dynamic properties of cable and soil, the temperatures respond slowly to a step change in current, enabling the operator to overload the cable during a short time in emergency situations.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-functionality\">Functionality<\/h3>\n\n\n\n<p>Vision Cable Analysis calculates:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Cyclic rating (a full week daily 24-hour cycles)<\/li>\n\n\n\n<li>Emergency rating<\/li>\n\n\n\n<li>Step response<\/li>\n<\/ul>\n\n\n\n<p>These calculations show how much more than the continuous current rating the cables can conduct in case of a cyclic varying load. The cyclic rating depends on the shape of the daily load cycle. These calculations also show how many extra loads can be added to the cable in case of emergencies. The emergency current rating strongly depends on the starting temperature and the emergency duration.<\/p>\n\n<\/div>\n\n\n<div class=\"ptp-column\">\n\t\n<div class=\"ptp-image\">\n\t\t\t<figure class=\"ptp-image__image-wrapper\">\n\t\t\t<img decoding=\"async\" width=\"1607\" height=\"1029\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-IEC60853.png\" class=\"ptp-image__image\" alt=\"\" loading=\"lazy\" srcset=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-IEC60853.png 1607w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-IEC60853-300x192.png 300w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-IEC60853-1024x656.png 1024w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-IEC60853-768x492.png 768w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-IEC60853-1536x984.png 1536w, https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/vision-cable-analysis-IEC60853-1x1.png 1w\" sizes=\"auto, (max-width: 1607px) 100vw, 1607px\" \/>\t\t<\/figure>\n\t<\/div>\n\n<\/div>\n\n<\/div>\n\n\t<\/div>\n<\/section>\n\n\n<section class=\"block ptp-columns\">\n\t<div class=\"container\">\n\t\t\n<div class=\"ptp-columns-row layout-100\">\n\t\n<div class=\"ptp-column\">\n\t\n\n<h2 class=\"wp-block-heading\" id=\"h-cable-types\">Cable types<\/h2>\n\n<\/div>\n\n<\/div>\n\n\n<div class=\"ptp-columns-row layout-50-50\">\n\t\n<div class=\"ptp-column\">\n\t\n\n<p>The starting point of Vision Cable Analysis calculations is always the construction of the cable. The program works with all common single- and three-core cables using the known insulation and construction materials.<\/p>\n\n\n\n<p>Each cable type can be inspected in detail and edited in the cable editor. With this cable editor the standard supplied cable database can easily be adapted and expanded.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Underground and above-ground<\/h4>\n\n\n\n<p>Vision Cable Analysis can calculate the ampacity for underground and aboveground cables. The program lets you easily adjust the conditions of the cable connections.<\/p>\n\n<\/div>\n\n\n<div class=\"ptp-column\">\n\t\n\n<p>For underground cables, depth and position are the most important factors. Nearby heat sources can be added.<\/p>\n\n\n\n<p>Vision Cable Analysis calculates the cable current rating for those cases:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>the soil does not dry out,<\/li>\n\n\n\n<li>the soil partially dries out (two-zone approximate physical model) and drying-out of the soil is to be avoided.<\/li>\n<\/ul>\n\n<\/div>\n\n<\/div>\n\n\t<\/div>\n<\/section>\n\n\n<div class=\"block link-list-wrapper\">\n\t<div class=\"container\">\n\t\t\n\n<h2 class=\"wp-block-heading\" id=\"h-download\">Download<\/h2>\n\n\n\n<p>You can download the latest version of Vision Cable Analysis here. Without a license, Vision Cable Analysis can only be used in demonstration mode. For a license or more information, contact\u00a0<a href=\"mailto:info@phasetophase.nl\">info@phasetophase.nl<\/a>.<\/p>\n\n\n<div class=\"link-list-container\">\n\t<ul class=\"link-list\">\n\t\t\n\t<li class=\"link-list__item\">\n\t\t<a href=\"https:\/\/www.phasetophase.nl\/en\/downloadportal\/\" class=\"\" target=\"_blank\">\n\t\t\t<span>Download Vision Cable Analysis<\/span>\n\t\t\t <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"11\" height=\"19\" viewBox=\"0 0 11 19\" fill=\"none\"><path d=\"M1.54785 17.3069L9.46204 9.3927L1.54785 1.47852\" stroke=\"white\" stroke-width=\"2.63806\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \t\t<\/a>\n\t<\/li>\n\t\n\t<\/ul>\n<\/div>\n\n\t<\/div>\n<\/div>\n\n\n<section class=\"block block-slider\">\n\t\t\t<div class=\"container\">\n\t\t\t<h2>Our products<\/h2>\n\t\t<\/div>\n\t\t<div class=\"cards-slider swiper\">\n\t\t<div class=\"swiper-wrapper\">\n\t\t\t\n<div class=\"swiper-slide\">\n\t\n<article>\n\t\t\t<a href=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-network-analysis\/\" target=\"_self\" class=\"card card--slider\">\n\t\t\t\n\t\t\t\t\t\t\t<figure class=\"card__image\">\n\t\t\t\t\t<div class=\"image__inner\">\n\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"250\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Network-Analysis_knop-400x250.png\" class=\"attachment-card size-card\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/figure>\n\t\t\t\t\t\t<div class=\"card__content\">\n\t\t\t\t<h3 class=\"card__title\">Vision Network Analysis<\/h3>\t\t\t\t\t\t\t\t\t\t\t\t\t<p class=\"card__paragraph\">Planning, design and control of transport, distribution and industrial grids.<\/p>\n\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t\t <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"32\" height=\"33\" viewBox=\"0 0 32 33\" fill=\"none\"><path d=\"M12.2144 24.3889L20.1285 16.4747L12.2144 8.56055\" stroke=\"#5D5D61\" stroke-width=\"2.63806\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \n\t\t\t\t<\/a>\n\t<\/article>\n<\/div>\n\n\n<div class=\"swiper-slide\">\n\t\n<article>\n\t\t\t<a href=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/gaia-lv-network-design\/\" target=\"_self\" class=\"card card--slider\">\n\t\t\t\n\t\t\t\t\t\t\t<figure class=\"card__image\">\n\t\t\t\t\t<div class=\"image__inner\">\n\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"250\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Gaia-LV-Network-Design_knop-400x250.png\" class=\"attachment-card size-card\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/figure>\n\t\t\t\t\t\t<div class=\"card__content\">\n\t\t\t\t<h3 class=\"card__title\">Gaia LV Network Design<\/h3>\t\t\t\t\t\t\t\t\t\t\t\t\t<p class=\"card__paragraph\">Design of LV grids based on both technical and economical criteria<\/p>\n\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t\t <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"32\" height=\"33\" viewBox=\"0 0 32 33\" fill=\"none\"><path d=\"M12.2144 24.3889L20.1285 16.4747L12.2144 8.56055\" stroke=\"#5D5D61\" stroke-width=\"2.63806\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \n\t\t\t\t<\/a>\n\t<\/article>\n<\/div>\n\n\n<div class=\"swiper-slide\">\n\t\n<article>\n\t\t\t<a href=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cloud-solution\/\" target=\"_self\" class=\"card card--slider\">\n\t\t\t\n\t\t\t\t\t\t\t<figure class=\"card__image\">\n\t\t\t\t\t<div class=\"image__inner\">\n\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"250\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Cloud-Solutionrknop-400x250.png\" class=\"attachment-card size-card\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/figure>\n\t\t\t\t\t\t<div class=\"card__content\">\n\t\t\t\t<h3 class=\"card__title\">Vision Cloud Solution<\/h3>\t\t\t\t\t\t\t\t\t\t\t\t\t<p class=\"card__paragraph\">Detailed insight into entire distribution networks.<\/p>\n\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t\t <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"32\" height=\"33\" viewBox=\"0 0 32 33\" fill=\"none\"><path d=\"M12.2144 24.3889L20.1285 16.4747L12.2144 8.56055\" stroke=\"#5D5D61\" stroke-width=\"2.63806\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \n\t\t\t\t<\/a>\n\t<\/article>\n<\/div>\n\n\n<div class=\"swiper-slide\">\n\t\n<article>\n\t\t\t<a href=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-grid-navigator\/\" target=\"_self\" class=\"card card--slider\">\n\t\t\t\n\t\t\t\t\t\t\t<figure class=\"card__image\">\n\t\t\t\t\t<div class=\"image__inner\">\n\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"250\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Grid-Navigator_knop-400x250.png\" class=\"attachment-card size-card\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/figure>\n\t\t\t\t\t\t<div class=\"card__content\">\n\t\t\t\t<h3 class=\"card__title\">Vision Grid Navigator<\/h3>\t\t\t\t\t\t\t\t\t\t\t\t\t<p class=\"card__paragraph\">Information from power grids on geographical backgrounds<\/p>\n\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t\t <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"32\" height=\"33\" viewBox=\"0 0 32 33\" fill=\"none\"><path d=\"M12.2144 24.3889L20.1285 16.4747L12.2144 8.56055\" stroke=\"#5D5D61\" stroke-width=\"2.63806\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \n\t\t\t\t<\/a>\n\t<\/article>\n<\/div>\n\n\n<div class=\"swiper-slide\">\n\t\n<article>\n\t\t\t<a href=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-fault-finder\/\" target=\"_self\" class=\"card card--slider\">\n\t\t\t\n\t\t\t\t\t\t\t<figure class=\"card__image\">\n\t\t\t\t\t<div class=\"image__inner\">\n\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"250\" src=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Fault-Finder_knop-400x250.png\" class=\"attachment-card size-card\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/figure>\n\t\t\t\t\t\t<div class=\"card__content\">\n\t\t\t\t<h3 class=\"card__title\">Vision Fault Finder<\/h3>\t\t\t\t\t\t\t\t\t\t\t\t\t<p class=\"card__paragraph\">Fast fault localisation by using measurements and simulation<\/p>\n\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t\t <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"32\" height=\"33\" viewBox=\"0 0 32 33\" fill=\"none\"><path d=\"M12.2144 24.3889L20.1285 16.4747L12.2144 8.56055\" stroke=\"#5D5D61\" stroke-width=\"2.63806\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \n\t\t\t\t<\/a>\n\t<\/article>\n<\/div>\n\n\t\t<\/div>\n\t\t<button class=\"slider-block__button-prev\">\n\t\t\t<?xml version=\"1.0\" encoding=\"UTF-8\"?> <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"49\" height=\"49\" viewBox=\"0 0 49 49\" fill=\"none\"><path d=\"M2.12156 2.22667L45.7728 0.605469L48.0963 48.6582H0.951172L2.12156 2.22667Z\" fill=\"#0077B0\"><\/path><path d=\"M21 30.4834L27 24.4834L21 18.4834\" stroke=\"white\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \t\t<\/button>\n\t\t<button class=\"slider-block__button-next\">\n\t\t\t<?xml version=\"1.0\" encoding=\"UTF-8\"?> <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"49\" height=\"49\" viewBox=\"0 0 49 49\" fill=\"none\"><path d=\"M2.12156 2.22667L45.7728 0.605469L48.0963 48.6582H0.951172L2.12156 2.22667Z\" fill=\"#0077B0\"><\/path><path d=\"M21 30.4834L27 24.4834L21 18.4834\" stroke=\"white\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><\/path><\/svg> \t\t<\/button>\n\t\t<div class=\"swiper-pagination\"><\/div>\n\t<\/div>\n<\/section>\n\n\n<section class=\"call-to-action\">\n\t<div class=\"container\">\n\t\t<div class=\"column\">\n\t\t\t\n\n<h2 class=\"wp-block-heading\" id=\"h-instant-answer-to-your-question-please-contact-us\">Instant answer to your question?<br>Please contact us<\/h2>\n\n\t\t<\/div>\n\t\t<div class=\"column\">\n\t\t\t\t\t\t\t<a href=\"https:\/\/www.phasetophase.nl\/en\/contact\/\" class=\"button button--secondary\">\n\t\t\t\t\tContact us\t\t\t\t<\/a>\n\t\t\t\t\t<\/div>\n\t<\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":199,"parent":175,"menu_order":11,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"editor_notices":[],"footnotes":""},"class_list":["post-219","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.6 (Yoast SEO v27.6) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Vision Cable Analysis - Phase to Phase<\/title>\n<meta name=\"description\" content=\"Vision Cable Analysis enables you to easily calculate the load capacity of cables. The program uses the IEC 60287 and IEC 60853 standard.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cable-analysis\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Vision Cable Analysis\" \/>\n<meta property=\"og:description\" content=\"Vision Cable Analysis enables you to easily calculate the load capacity of cables. The program uses the IEC 60287 and IEC 60853 standard.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cable-analysis\/\" \/>\n<meta property=\"og:site_name\" content=\"Phase to Phase\" \/>\n<meta property=\"article:modified_time\" content=\"2024-04-28T19:34:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Cable-Analysis-Ampere-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"897\" \/>\n\t<meta property=\"og:image:height\" content=\"795\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/vision-cable-analysis\\\/\",\"url\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/vision-cable-analysis\\\/\",\"name\":\"Vision Cable Analysis - Phase to Phase\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/vision-cable-analysis\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/vision-cable-analysis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.phasetophase.nl\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2024\\\/04\\\/Vision-Cable-Analysis-Ampere-1.png\",\"datePublished\":\"2024-04-17T18:41:33+00:00\",\"dateModified\":\"2024-04-28T19:34:38+00:00\",\"description\":\"Vision Cable Analysis enables you to easily calculate the load capacity of cables. The program uses the IEC 60287 and IEC 60853 standard.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/vision-cable-analysis\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/vision-cable-analysis\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/vision-cable-analysis\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.phasetophase.nl\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2024\\\/04\\\/Vision-Cable-Analysis-Ampere-1.png\",\"contentUrl\":\"https:\\\/\\\/www.phasetophase.nl\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2024\\\/04\\\/Vision-Cable-Analysis-Ampere-1.png\",\"width\":897,\"height\":795},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/vision-cable-analysis\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products and services\",\"item\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Products\",\"item\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/products-and-services\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Vision Cable Analysis\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/\",\"name\":\"Phase to Phase\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.phasetophase.nl\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Vision Cable Analysis - Phase to Phase","description":"Vision Cable Analysis enables you to easily calculate the load capacity of cables. The program uses the IEC 60287 and IEC 60853 standard.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cable-analysis\/","og_locale":"en_US","og_type":"article","og_title":"Vision Cable Analysis","og_description":"Vision Cable Analysis enables you to easily calculate the load capacity of cables. The program uses the IEC 60287 and IEC 60853 standard.","og_url":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cable-analysis\/","og_site_name":"Phase to Phase","article_modified_time":"2024-04-28T19:34:38+00:00","og_image":[{"width":897,"height":795,"url":"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Cable-Analysis-Ampere-1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cable-analysis\/","url":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cable-analysis\/","name":"Vision Cable Analysis - Phase to Phase","isPartOf":{"@id":"https:\/\/www.phasetophase.nl\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cable-analysis\/#primaryimage"},"image":{"@id":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cable-analysis\/#primaryimage"},"thumbnailUrl":"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Cable-Analysis-Ampere-1.png","datePublished":"2024-04-17T18:41:33+00:00","dateModified":"2024-04-28T19:34:38+00:00","description":"Vision Cable Analysis enables you to easily calculate the load capacity of cables. The program uses the IEC 60287 and IEC 60853 standard.","breadcrumb":{"@id":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cable-analysis\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cable-analysis\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cable-analysis\/#primaryimage","url":"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Cable-Analysis-Ampere-1.png","contentUrl":"https:\/\/www.phasetophase.nl\/wp-content\/uploads\/sites\/2\/2024\/04\/Vision-Cable-Analysis-Ampere-1.png","width":897,"height":795},{"@type":"BreadcrumbList","@id":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/vision-cable-analysis\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.phasetophase.nl\/en\/"},{"@type":"ListItem","position":2,"name":"Products and services","item":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/"},{"@type":"ListItem","position":3,"name":"Products","item":"https:\/\/www.phasetophase.nl\/en\/products-and-services\/products\/"},{"@type":"ListItem","position":4,"name":"Vision Cable Analysis"}]},{"@type":"WebSite","@id":"https:\/\/www.phasetophase.nl\/en\/#website","url":"https:\/\/www.phasetophase.nl\/en\/","name":"Phase to Phase","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.phasetophase.nl\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/pages\/219","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/comments?post=219"}],"version-history":[{"count":3,"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/pages\/219\/revisions"}],"predecessor-version":[{"id":377,"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/pages\/219\/revisions\/377"}],"up":[{"embeddable":true,"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/pages\/175"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/media\/199"}],"wp:attachment":[{"href":"https:\/\/www.phasetophase.nl\/en\/wp-json\/wp\/v2\/media?parent=219"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}